FoamPro Standard Components/Options

Model 1600 1601 2001 2002 3012
Dual Injector Selector (Requires MultiFlo) O O O
Electric Concentrate Management System O O O
Manual Concentrate Management System O O
Remote Start/Stop O O O O O
MultiFlo Interface O O O
Advanced Feature Controller O O O
System Schematic and Rating Placards O O O O O
Flow Sensor and Tee S S O O O
Main Waterway Check Valve O O O O O
Low-Level Tank Sensor (Required) O O O O O
Manifold Assembly O O O O O
Concentrate Cell O O O O
Solid State Contractor O O O O O
Off-Board Pickup Kit O O
Remote Simulated Flow O O

S = Standard, O = Optional

FoamPro Accessories & Options

Dual Injector Selector

(requires MultiFlo)

Allows choice of two different concentrate injection points. Ideal for high/low pressure fire pumps or high-flow (aerial/deluge), low-flow applications.

Availability:
2000 Series, 3012 Series

Electronic Concentrate Management System

Electronically-operated valve allows choice between two different concentrates. Flush mode prevents mixing, and interface with control head provides calibration and storage of performance results of each concentrate.

Availability:
2000 Series, 3012 Series

Manual Concentrate Management System

Manually-operated valve allows choice between two different concentrates. Flush mode prevents mixing, and interface with control head provides calibration and storage of performance results of each concentrate.

Availability:
2000 Series

Remote Start/Stop

Separately-mounted switch interfaces with digital control head allowing remote activation of the proportioner. Designed for in-cab pump & roll operations.

Availability:
1600 Series, 2000 Series, 3012

MultiFlo Interface

Provides calibration and flow totals for up to four different discharges.

Availability:
2000 Series, 3012

Advanced Feature Controller

Provides programmable choice of activation of proportioning manually by push of ON button or automatically-ON with engagement of fire pump. Ideal for CAFS and SOP’s directing foam use.

Availability:
2000 Series, 3012

System Schematic and Rating Placards

Attractive placard designed for the operator’s panel, listing system ratings or system schematics.

Availability:
1600 Series, 2000 Series, 3012

Flow Sensor and Tee

(required 2000, 3000)

Paddlewheel flow sensor reads fire pump discharge flow without restricting performance. Thread sizes (NPT & BSP) available: 1-1/2″, 2″, 2-1/2″, 3″ and 4″. Also machined for Victaulic coupling. An insertion paddlewheel flow sensor is available for pipe sizes larger than 4″. Magnetic flow sensors are available upon request.

Availability:
1600 Series (standard), 2000 Series, 3012

Main Waterway Check Valve

Prevents backflow to fire pump. Stainless Steel components and construction, rated for 450 psi (31 BAR) with NPT thread size or victaulic grooves for 1-1/2″, 2″, 2-1/2″, 3″ and 4″. Includes tapped injection and drain ports.

Availability:
1600 Series, 2000 Series, 3012

Manifold Assembly

All stainless steel manifold incorporating flow sensor, check valve, injection and drain ports. Victaulic connections in 1-1/2″, 2″, 2-1/2″, 3″ and 4″ reduce installation time.

Availability:
1600 Series, 2000 Series, 3012

Concentrate Cell

Polypropylene concentrate tanks with one-way vented cap available in 8, 12, or 20 gallon (30, 45 or 70 liter) capacities.

Availability:
1600 Series, 2000 Series, 3012

Low-Level Tank Sensor

(required)

Provides signal to display, notifying operator of low concentrate condition in foam cell. Available in top/bottom (shown above) or side mount.

Availability:
1600 Series, 2000 Series, 3012

Solid State Contactor

Electronically-controlled DC power switch superior to mechanical solenoids. Longer life and remote start/stop capability.

Availability:
1600 Series, 2000 Series, 3012

3012 Manual Override

Disengages automatic proportioning, allowing manual proportioning operation.

Availability:
3012

Off-Board Pickup Kit

Allows automatic on-demand selection of an on-board foam source or an off-board foam source. Provides automatic flushing when switching sources. Available in both a 1″ for the 2002 and 1 1/2″ for the 3012 system.

Availability:
Model 2002, 3012

Remote Simulated Flow

Separately mounted switch provides location flexibility for 1600 series simulated flow switch.

Availability:
1600 Series

TurboFoam Accessories and Options

Electric ABF Selector

The electric ABF selector is standard on the TFC400 models. It allows the operator to select Class A foam, Class B foam, or flushing operations from the push buttons on the control module. The selector is installed between the foam tanks and the foam pump assembly intake and has an input for flush water. The electric model is made up of three electric valves mounted on a manifold that controls the flow of foam concentrate or flush water into the system. On each of the valve covers there is a dial indicator to show the valve position and an allen head screw that allows for manual adjustment of the valve position.

Manual ABF Selector

The manual ABF selector is an option with the TFC200 models. It allows the operator to select Class A foam, Class B foam, or Flushing operations by rotating the ABF selector handle. The selector is connected between the foam tanks and the foam pump assembly intake and has an input for flush water. Two check valves are included with this option that must be installed between the foam tanks and the selector.

Electric Flush Valve

The electric valve is standard on the TFC300 models and an option with the TFC100/200 single tank systems. It is used to provide flush or prime capabilities for the concentrate pump.

Remote ON/OFF Switch & Indicator

The remote switch and indicator mirrors the control module ON/OFF button and LED on the control module.

Check Valve & Drain

  1. Includes a water way check valve, check valve injector port, and
    a drain.
  2. Includes a flow sensor mount, water way check valve, check valve injector port, and a drain.

TankVision or Tank Float Switch

A TankVision sensor or tank float switch is required to be installed in the foam tank to provide the tank empty signal to the control module. The TankVision is connected to the control module on the datalink and provides tank volume data. If a tank float switch is installed, it is connected to the tank empty inputs on the control module.

Information Placards

These helpful informational reference placards provide capacity specifications, plumbing schematics, and operator instructions.

Plumbing Components

  • Paddlewheel Discharge Flow Sensor
  • Strainer
  • Check Valve

Documents & Downloads